User manual ACER ASPIRE M3-581
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACER ASPIRE M3-581. We hope that this ACER ASPIRE M3-581 user guide will be useful to you.
You may also download the following manuals related to this product:
ACER ASPIRE M3-581 ǔ (97559 ko)
Manual abstract: user guide ACER ASPIRE M3-581
Detailed instructions for use are in the User's Guide.
[. . . ] Record the model number, serial number, purchase date, and place of purchase information in the space provided below. The serial number and model number are recorded on the label affixed to your system. All correspondence concerning your unit should include the serial number, model number, and purchase information. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopy, recording, or otherwise, without the prior written permission of Acer Incorporated.
Model Number : _________________________________ Serial Number: ___________________________________ Purchase Date: ___________________________________ Place of Purchase: ________________________________
Acer and the Acer Logo are registered trademarks of Acer Inc. [. . . ] Follow the procedures below to connect the cables (see figure on page 24): 1. Attach one end of the second cable to the second connector on the ESM. Attach the other end of this cable to a host.
Note: For more information on the host connectors, refer to the documentation supplied with the host system.
1
Enclosure must be powered on to see the LEDs.
24
3 Cabling and configuration
To Host ID 7 To Host ID 7
1 2
1 2
Mute
0
ESM
I
I
0
TSM
The ESM and TSM can be in either I/O slot of the enclosure.
SCSI ID Assignments shown from front of enclosure.
The Bus A LED2 will be on for top connector to indicate that first seven disks are on Bus A. The Bus B LED will be on for bottom connector to indicate that remaining seven disks are on Bus B. The Environmental Services (ES) LED is ON for both the ESM and TSM, to show that both of their ES blocks are active.
Note: Both I/O modules are at ID 15. For information on the I/O module LED, see page 20.
2
Enclosure must be powered on to see the LEDs.
25
Single CSM and TSM Configuration
This configuration can be cabled as either a Single (Joined) SCSI Bus or as a Dual (Split) SCSI Bus configuration.
Cabling the single (joined) SCSI bus configuration
One host cable is required for this configuration. When viewed from the rear there should be a CSM installed in one I/O slot and a TSM in the other. Follow the procedures below to connect the cable (see figure below): 1. Attach the other end of this cable to the host.
To Host ID 7
1 2
1 2
Mute
0
CSM
I
I
0
TSM
The CSM and TSM can be in either I/O slot of the enclosure.
SCSI ID Assignments shown from front of enclosure.
Note: For information on the host connectors, refer to the documentation supplied with it.
26
3 Cabling and configuration
The Bus A LED will be ON3 to indicate that all disks are on Bus A. The Environmental Services (ES) LED is ON for the TSM in this example to show that its ES block is the active block.
Note: Both I/O modules are at ID 15. Only one module will be active at any one time and the other will be on standby. Jumpers installed on the I/O modules determine how the enclosure powers up and how the disk drives spin up. The following section describe the jumper settings.
Altos S300 series jumper settings
The Altos S300 series enclosure jumpers are located on the I/O Modules (ESM and CSM). By installing or removing these jumpers the following options may be set.
Note: For information on the I/O module LED, see page 20.
Power up
With this option enabled, the enclosure will power up automatically when the host system is powered on. Switch on the enclosure (switches on PSU's at rear of enclosure). Power on the host system and the enclosure will power on also.
To disable this option, install a jumper at location JP13 on the ESM and CSM (whichever is installed). If two CSMs are installed, the jumper should be installed on both CSMs.
Remote start up
If you select this option, the disk drives will not spin up until a spin up command is issued by the host system (even though the enclosure is powered on). To enable this feature, install a jumper at location JP12 on the ESM and CSM (whichever is installed). If two CSMs are installed, the jumper should be installed on both CSMs.
32
3 Cabling and configuration
Delayed Start
If you select this option, the disk drives will spin up sequentially i. e. To enable this feature, install a jumper at location JP11 on the ESM and CSM (whichever is installed). If two CSMs are installed, the jumper should be installed on both CSMs.
Powering on an AC enclosure
1. Ensure all cables have been attached as described in the preceding sections. [. . . ] Es wird empfohlen, die Installation des Laufwerkfachs von mindestens zwei Personen vornehmen zu lassen. Försiktighet: När en utrustningshylla installeras eller avlägsnas ska all strömtillförsel bortkopplas och alla skivdrivenheter avlägsnas. Det rekommenderas att du arbetar med minst en person till när en skivhylla ska installeras. Detta är nödvändigt för att förhindra personliga skador och skador på hyllan. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ACER ASPIRE M3-581
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ACER ASPIRE M3-581 will begin.