User manual LG GR-359SNQ

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG GR-359SNQ. We hope that this LG GR-359SNQ user guide will be useful to you.


LG GR-359SNQ : Download the complete user guide (1874 Ko)

You may also download the following manuals related to this product:

   LG GR-359SNQ (30081 ko)
   LG GR-359SNQ (1882 ko)
   LG GR-359SNQ (1941 ko)
   LG GR-359SNQ (1882 ko)

Manual abstract: user guide LG GR-359SNQ

Detailed instructions for use are in the User's Guide.

[. . . ] If the fuse on PC board is broken please change it with the type of T 3. 15A 250V. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less than 3. 5mm. Such means for disconnection must be incorporation in the fixed wiring. DISPOSING OF THE UNIT Before throwing out the device, it is necessary to pull back the battery cells and get rid of them safely for recycling reasons. If pipes are removed incorrectly, refrigerant may blow out and come into contact with your skin, causing injury. [. . . ] Please recycle or dispose of the packaging material for this product in an environmentally responsible manner. OTHERS Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor. The appliance is not intended for use by young children or infirm persons without supervision: Young children should be supervised to ensure that they do not play with the appliance. Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency. E-2 Contents PREPARING YOUR AIR CONDITIONER Safety Precautions Air Conditioning Unit-Main Parts and Control Panel 2 4 5 6 6 7 7 7 OPERATION YOUR AIR CONDITIONER Cooling Your Room Airing Your Room Switching the Air Conditioner Off Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction Vertically RECOMMENDATIONS FOR USE Temperature and Humidity Ranges Cleaning Your Air Conditioner Solving Common Problems Technical Specitications 9 10 11 8 INSTALLATION The illustrations in the step-by-step procedures use four different symbols: CA U T I O N "The high inrush current of the starting compressor motor can have adverse effects to the operation of other equipment under unfavorable mains conditions. This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker. " Before connection this equipment to the power supply system, please report to your suply authority and obtain the consent. Do not connect other electric appliances to the same supply lines. The maximum permissible system impedance at the power junction box is 0. 24 ohms. Usually, the maximum permissible mains impedance will not be exceeded when the branch to the power outlet is fed from a junction box with a rated current of 32A. AW18 ** E-3 ENGLISH Air Conditioning Unit - Main Parts and Control Panel The desing and shape are subject to change according to the model. Air Outlet Inner air flow blades (right/left orientation) Air inlet(Inside) The air filter is located in side Outer air flow blades (up/down orientation) Air inlet (Outside) Ventilation lever Power Cable Power plug The type of the power plug may differ according to the type of local power supply. Operating mode selection dial Temperature control dial Coolest Air flow blade swing switch E-4 Cooling Your Room ENGLISH You must select the Cool mode if you wish to lower the temperature in your room. High fan speed Between HIGH and LOW Low fan speed Result: HI COOL MED COOL LOW COOL The air conditioner starts up in Cool mode. 2 To adjust the temperature, turn the temperature control dial to the desired position. Result: The air conditioner starts cooling if the room temperature is higher than the selected temperature. 3 To control the direction of the air flow, refer to page 7 E-5 Airing Your Room If the atmosphere in your room is stale, you can air it using the Fan feature and if necessary, evacuate the stale air outside. 1 If you wish to evacuate stale air outside, push the ventilation lever on the front of the unit to the right and the open position ( ). Set the operating mode selection dial to "LOW FAN" and let it run of a few hours to dry the inside of the air conditioner thoroughly. Have not used the air conditioner for a long period of time E-8 Solving Common Problems ENGLISH Before contacting the after-sales service, perform the following simple checks. PROBLEM The air conditioner does not operate at all EXPLANATION / SOLUTION Check that the circuit breaker used for the air conditioner has not been triggered. Check that the power cable is plugged into a wall socket and the socket is switched on, if necessary. Check that the correct operating mode has been selected (cooling or airing). The air conditioner does not cool Check that the correct operating mode has been selected. Dust may be blocking the air filter; refer to page 9 cleaning instructions. Check that there is no obstacle blocking the air flow into or out of the unit. The air flow direction does not change when you set the air flow blade swing switch to the on position Odours are permeated in the room during air conditioning Check that the air conditioner has been switched on; if necessary, turn the operating mode selection dial; refer to page 7. Air the room. E-9 Technical Specifications Design and specifications are subject to change without notice. Model Power Supply 115V~, 60Hz 220V(230V)~, 60Hz 230/208V~, 60Hz 200-220V~, 50Hz 220-240V~, 50Hz ******AA/AB ******BA/BB/BC/BD ******CA/CB ******DA/DB ******EA/EB/EC/ED E-10 Installation (for 60Hz) ENGLISH 1 Electrical Requirements For personal safety: This appliance must be properly grounded. Do not, under any circumstances, cut or remove the third grounding prong from the power cord. [. . . ] Do not, under any circumstances, cut or remove the third grounding prong from the power cord. We recommend that you do not use an extension cord or an adapter plug with this appliance. Follow national electrical codes or local codes and ordinances. 115V 15 AMP Circuit "parallel" type 230V/208V 20 AMP circuit "perpendicular" type 230V/208V 15AMP circuit "tandem" type 230V/208V 30 AMP circuit "tandem" type If the electric supply provided does not meet the above specifications, call a licensed electrician. Aluminum house wiring may pose special problemsconsult a qualified electrician. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-359SNQ




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-359SNQ will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.