User manual LG GR-L207DVZA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG GR-L207DVZA. We hope that this LG GR-L207DVZA user guide will be useful to you.


LG GR-L207DVZA : Download the complete user guide (4733 Ko)

You may also download the following manuals related to this product:

   LG GR-L207DVZA (4716 ko)
   LG GR-L207DVZA (5005 ko)
   LG GR-L207DVZA (5094 ko)
   LG GR-L207DVZA (4951 ko)

Manual abstract: user guide LG GR-L207DVZA

Detailed instructions for use are in the User's Guide.

[. . . ] Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selecting Heat Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The indoor unit beeps. 2 Press the Result: button on the remote control until is displayed. The air conditioner changes from Cool or Heat mode automatically, depending on the current temperature. You can change modes at any time. Note 3 Press the button to adjust the temperature until the required temperature is displayed. button: Each time you press the Result: - The temperature adjusts by 1°C - The indoor unit beeps 4 Press the displayed. button to select the fan speed until the required setting is Result: Automatic (rotated : ) Low Medium High Each time you press the button, the indoor unit beeps. 5 To control the airflow direction, refer to page 21. E-13 Selecting Cool Mode You can select Cool mode if you want to cool your room. You can adjust the temperature and the fan speed when cooling. 1 Press the Result: (On/Off) button. The indoor unit beeps. 2 Press the Result: Note button on the remote control until is displayed. You can change modes at any time. 3 Press the button to adjust the temperature until the required temperature is displayed. For the first 3~5 minutes, the fan may not operate to prevent cool air from flowing out of the indoor unit. Silence mode( ) makes the noise quieter during operating the indoor unit in the Heat mode. Note 5 To control the airflow direction, refer to page 21. E-15 Selecting Dry Mode Select Dry mode if you want to dehumidify your room. You can adjust the temperature in this mode. 1 Press the Result: (On/Off) button. The indoor unit beeps. 2 Press the Result: button on the remote control until is displayed. If you select this function in Dry or Fan mode, the mode changes to Auto mode. 3 Press the button again to stop the Turbo Function before the end of the 30-minute period. Result: The air conditioner is reset automatically to the previous setting. 4 To control the airflow direction, refer to page 21. E-20 Adjusting the Airflow Direction Vertically ENGLISH You can adjust the airflow direction vertically. The outer airflow blade moves up and down to increase the efficiency of the cooling or heating operation. 1 Press the Result: button until the required direction is set. The outer blade is adjusted vertically. 2 Press the button again to move the blade up and down automatically during operation. 3 Press the Note button again to stop the blade moving up and down. set to the default position. Adjusting the Airflow Direction Horizontally You can adjust airflow direction horizontally manually. The inner blades with small fins move the air in the desired direction. 1 Adjust the inner blades by moving them left or right. It may cause injury on your fingers. E-21 Setting the On Timer You can set the On Timer to turn on the air conditioner automatically at the appointed time within a range of 30 minutes to 24 hours. 1 Press the button until the desired time is displayed to set the On Timer. You can set the time between 0. 5 hour and 24 hours. 2 Press the Result: button to complete the setting. The selected mode and the temperature on the display disappear after 10 seconds. The air conditioner turns on automatically at the appointed time and the On Timer setting disappears. 3 Press the button until the desired mode is displayed at the top of the remote control to select the mode in advance. Result: The air conditioner operates in the selected mode when it is turned on. To Cancel the On Timer If you no longer wish to use the On Timer that you have set, you can cancel it at any time. 1 To cancel the On Timer, press the timer setting disappears. button one or more times until the 2 Press the Note button. [. . . ] 1 Open the upper front grille by pulling the lower right and left tabs of the grille. Deodorizing Filter 2 Pull out the deodorizing and Bio filter. 4 Insert the filters into the original position. Note You can change the position of filters with each other. Bio Filter 5 Close the front grille. E-25 Temperature and Humidity Ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. MODE OPERATING CONDITIONS Indoor temp: 16°C~32°C Indoor humidity: below 80% Outdoor temp: 09/12FC 09/12NSA 10°C~43°C 09/12NSB 18/24 -10°C~43°C 09/12FC 09/12NSA -10°C~24°C 09/12NSB 18/24 -15°C~24°C IF OUT OF CONDITIONS - A safety device will stop continuously the system functioning; - Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor; - A safety device will stop continuously the system functioning; - A safety device will stop continuously the system functioning; - Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor; 220V-240V~50Hz 198V min. -264V max. COOL Indoor temp: below 27°C HEAT Outdoor temp: Indoor temp: 16°C~32°C Indoor humidity: below 80% DRY Outdoor temp: 09/12FC 09/12NSA 10°C~43°C 09/12NSB 18/24 -10°C~43°C POWER SUPPLY Single phase rated voltage minimum and maximum limit Any damage occurs out of condition specified cannot be covered by product warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-L207DVZA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-L207DVZA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.