User manual PANASONIC S224ME2E5
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC S224ME2E5. We hope that this PANASONIC S224ME2E5 user guide will be useful to you.
Manual abstract: user guide PANASONIC S224ME2E5
Detailed instructions for use are in the User's Guide.
[. . . ] This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. Matters to be observed
2
• Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help. This air conditioner is designed to give you comfortable room conditions. [. . . ] Outdoor Unit
2WAY (ME1 type) Cooling Heating 3WAY (MF2 type) Cooling Heating Cooling & Heating
Indoor temperature range
Outdoor temperature range
WARNING
Avoid the following locations for installation. Locations where excessively high heat-generating ob jects are placed. 14°C 25°C (*WBT) -10°C 46°C (*DBT) 16°C 30°C (*DBT) -25°C 15°C (*WBT) 14°C 25°C (*WBT) -10°C 46°C (*DBT) 15°C 30°C (*DBT) -20°C 18°C (*WBT) ― -10°C 24°C (*DBT)
Attention:
Avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa. (To protect the air conditioner from heavy corrosion)
*DBT: Dry bulb temperature *WBT: Wet bulb temperature
When used in FRESH AIR INTAKE MODE
Outdoor Unit
2WAY (ME1 type) Cooling Heating 3WAY (MF2 type) Cooling Heating Cooling & Heating
ON
Indoor temperature range
14°C 16°C 14°C 15°C
Outdoor temperature range
46°C (*DBT) 16°C (*DBT) 46°C (*DBT) 16°C (*DBT) 24°C (*DBT)
Wiring
All wiring must conform to the local electrical codes. ) Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring. ς
25°C (*WBT) 22°C 30°C (*DBT) -5°C
25°C (*WBT) 22°C 30°C (*DBT) ― -5°C -5°C
Operation Preparation
Turn the power mains on 5 hours before the start of operation. ς
*DBT: Dry bulb temperature *WBT: Wet bulb temperature If the unit is operated for long hours excluding the conditions listed in the table, operation will be stopped and the unit leads to problems. NOTE
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time. Tips for Energy Saving
Avoid
Do not block the air intake and outlet of the unit. (If either is obstructed, the unit will not function well, causing malfunction. ) During cooling operation, use sunshades, blinds or cur tains to prevent direct sunlight from entering the room. ς ‘‘DRY’’ operation
Defrosting
Once the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically. When the outdoor unit is turned off, the indoor unit fan will stop, too. (To prevent the humidity in the room from rising again) When the room temperature is more likely to reach the level that was set, the fan speed is set to ‘‘breeze’’ (light wind) automatically. ‘DRY’’ operation is not possible if the outdoor tempera ture is 15 °C or less. 2Heating operation resumes after several minutes: The indoor unit fan remains stopped (or
it will run at a very slow speed) until the indoor heat exchanger coil warms up sufficiently. ς Should the power failure occurs while the unit is running
When the unit automatically resumes operation after temporary power failure, it uses the same settings before the power was cut off. Indb 6
2014/09/18 9:31:42
FRESH AIR INTAKE MODE Only
Setting the Operation mode
This product brings outdoor fresh air into the building and adjusts and supplies the air with nearly current indoor temperature. Automatic cooling and heating operation mode
Due to the temperature difference between the outdoor air and preset temperature in remote controller, cooling or heating operation can be automatically selected. In the case of group control, the setting is possible when all of the indoor units in the same refrigerant circuit consist of one group. 6) 1 Cooling operation mode : In case that the outdoor temperature is 5°C higher than the preset temperature in remote controller. : In case that the outdoor temperature and preset temperature in remote controller are within 2 Fan operation mode ±5°C. [. . . ] The fan continues to rotate even after the operation is stopped using the remote controller. *DBT: Dry bulb temperature *WBT: Wet bulb temperature Jika unit dioperasikan dalam waktu lama di bawah kondisi seperti dalam tabel, operasi akan diakhiri dan unit akan mengalami masalah. Setelah unit luar ruang dimatikan, kipas unit dalam ruang juga akan mati. 2Operasi pemanasan akan kembali aktif setelah beberapa menit: Kipas unit dalam ruang tetap mati
Jika daya gagal selama unit beroperasi
102
OI_00_286020_EU_all. [. . . ]